Équipements électromécaniques
43 produits au total
Engins de construction, eau et assainissement, chauffage-ventilation, protection incendie, alimentation et distribution électriques et équipements électromécaniques intelligents, couvrant toutes les catégories d'installations techniques du bâtiment.

PVC Junction Box (Flush & Surface Mount)
PVC gang boxes for concealed or surface installation: 77×77–164×77mm, heights 22–70mm, with active fixing feet or metal brackets, knock-out entries for dn20/dn25 conduit; matching box covers available; white.

PVC Round Wiring Duct 70x15
Size: 70x15 mm Length: 2m Material: PVC, self-extinguishing

Flooded-type ground source heat pump unit (groundwater type, KWS-400 class)
Model: KWS-400FORGWB (R22, groundwater type) Cooling capacity: 385 kW (EER 6.39) Heating capacity: 402 kW (COP 5.03) Compressor: semi-hermetic twin-screw compressor, star-delta start Refrigerant: R22 Heat exchanger: flooded evaporator + shell-and-tube condenser Power supply: 380V/3N~/50Hz, water chamber pressure 1.0 MPa

Flooded-type ground source heat pump unit (buried pipe type/surface water type, KWS-700 class)
Model: KWS-700FORGLB (R22, ground-loop/surface-water type) Cooling capacity: 730 kW Heating capacity: 746 kW Compressor: semi-hermetic twin-screw compressor Refrigerant: R22 Power supply: 380V/3N~/50Hz, water-side pressure 1.0 MPa

Flooded water-cooled screw chiller (R134a, KWS-400 class)
Model: KWS-400F3CB (R134a, cooling-only type) Cooling capacity: 390 kW Input power: 65.4 kW COP: 6.0, IPLV: 6.91 Chilled water flow: 67 m³/h, water pressure drop 70 kPa, connection DN125 Cooling water flow: 84 m³/h, water pressure drop 73 kPa, connection DN125 Compressor: semi-hermetic twin-screw compressor ×1, star-delta start, multi-stage/stepless capacity control Dimensions (L×W×H): 3510×1200×1945 mm Unit weight 2780 kg, operating weight 3000 kg Power supply: 380V/3N~/50Hz, water-side pressure 1.0 MPa

Variable-frequency flooded water-cooled screw chiller (R134a, KWS-900 class)
Model: KWS-900F3CBV (R134a, variable-frequency, cooling-only type) Cooling capacity: 890 kW Input power: 146.6 kW COP: 6.1, IPLV: 8.1 Compressor: semi-hermetic twin-screw compressor ×1, variable-frequency start, variable-frequency control Chilled water flow: 153 m³/h, connection DN150 Cooling water flow: 191 m³/h, connection DN150 Refrigerant: R134a Power supply: 380V/3N~/50Hz, water-side pressure 1.0 MPa (grooved coupling connection)

Screw-Type Air-Cooled Chiller (Heat Pump) Unit (R22, KAS-400 Class)
Model: KAS-400E0R (R22, heat pump type; cooling-only type KAS-400E0C) Cooling capacity: 413 kW Cooling operating power: 127.0 kW Heating capacity: 455 kW Compressor: semi-hermetic twin-screw compressor, capacity control 25%/50%/75%/100% Refrigerant: R22 Power supply: 380V/3N~/50Hz Cooling capacity range of the same series: 252~805 kW; multiple units can be modularly combined

Inverter Screw-Type Air-Cooled Chiller (Heat Pump) Unit (R134a, KAS-460 Class)
Model: KAS-460E3RV (R134a, heat pump type; cooling-only type KAS-460E3CV) Cooling capacity: 460.0 kW Cooling operating power: 136.1 kW Compressor: inverter semi-hermetic twin-screw compressor Refrigerant: R134a Power supply: 380V/3N~/50Hz Cooling capacity range of the same series: 230~770 kW

Standard control cable 0.6/1 kV (rubber insulation and sheath, 7×1.5–24×1.5 mm² range)
Rated voltage: 0.6/1 kV (max. AC 0.7/1.2 kV; AC test 2.5 kV) Size range: 7×1.5 / 12×1.5 / 18×1.5 / 24×1.5 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: rubber insulation + high-strength filler + anti-torsion layer + black rubber outer sheath Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min), single-row multi-layer reeling drums (200 m/min) Max. tensile strength: 157–540 N Outer diameter / unit weight: 7×1.5 outer diameter 16.0–18.0 mm, 0.44 kg/m; 24×1.5 outer diameter 26.0–28.0 mm, 0.99 kg/m Standards: VDE 0250-814, VDE 0295

Standard control cable 0.6/1 kV (rubber insulation and sheath, 7×2.5–36×2.5 mm² range)
Rated voltage: 0.6/1 kV (max. AC 0.7/1.2 kV; AC test 2.5 kV) Size range: 7×2.5 / 12×2.5 / 18×2.5 / 24×2.5 / 30×2.5 / 36×2.5 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: rubber insulation + high-strength filler + anti-torsion layer + black rubber outer sheath Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min), single-row multi-layer reeling drums (200 m/min) Max. tensile strength: 262–1350 N Outer diameter / unit weight: 7×2.5 outer diameter 17.8–19.8 mm, 0.54 kg/m; 36×2.5 outer diameter 32.0–35.0 mm, 1.95 kg/m Standards: VDE 0250-814, VDE 0295

Copper braid shielded signal control cable 0.6/1 kV (3×(2×1)C–19×2.5+5×1.5(C) range)
Rated voltage: 0.6/1 kV (AC test 2.5 kV) Size range: 3×(2×1)C / 3×(2×1.5)C / 6×(2×1)C / 6×(2×1.5)C / 19×2.5+5×1.5(C) mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: rubber insulation + copper braid shield (C) + black rubber outer sheath Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: control and signal circuits for festoon systems and single-row multi-layer reeling drums Max. tensile strength: 90–938 N Outer diameter / unit weight: 3×(2×1)C outer diameter 22.5–24.5 mm, 0.65 kg/m; 19×2.5+5×1.5(C) outer diameter 33.0–36.0 mm, 1.60 kg/m Standards: VDE 0250-814, VDE 0295

Control cable for festoon systems 0.6/1 kV (12×2.5–24×2.5 mm² range)
Rated voltage: 0.6/1 kV (AC test 2.5 kV for control cores) Size range: 12×2.5 / 18×2.5 / 24×2.5 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: EPR insulation 3GI3 + inner sheath + polychloroprene outer sheath 5GM3 Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min) Max. tensile strength: 450–900 N Outer diameter / unit weight: 12×2.5 outer diameter 19.5–21.5 mm, 0.66 kg/m; 24×2.5 outer diameter 26.5–28.5 mm, 1.25 kg/m Standards: VDE 0250, VDE 0295

Control cable for spreader reeling drums or vertical applications 0.6/1 kV (18×2.5–30×2.5 mm² range)
Rated voltage: 0.6/1 kV (AC test 2.5 kV) Size range: 18×2.5* / 24×2.5* / 30×2.5(5×6×2.5) mm² (*cores arranged in multiple concentric layers) Conductor: VDE 0295 class 6 copper conductor Construction: special polymer insulation + central tensile reinforcement core + flexible inner sheath + anti-torsion layer + abrasion-resistant outer sheath Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -35 to +80 °C; mobile operation -25 to +80 °C Application: vertical reeling drums (240 m/min), cable supply systems (180 m/min) Max. tensile strength: 2000–4000 N Outer diameter / unit weight: 18×2.5 outer diameter 22.0–26.0 mm, 1.10 kg/m; 30×2.5 outer diameter 30.2–33.2 mm, 1.60 kg/m Standards: VDE 0250-814, VDE 0295

Control cable for spreader reeling drums or vertical applications 0.6/1 kV (42×2.5–54×2.5 mm² range, including 3.3 mm² large cross-section items)
Rated voltage: 0.6/1 kV (AC test 2.5 kV) Size range: 42×2.5(7×6×2.5) / 44×2.5* / 54×2.5(9×6×2.5) / 36×3.3(6×6×3.3) / 42×3.3(7×6×3.3) mm² Conductor: VDE 0295 class 6 copper conductor Construction: special polymer insulation + central tensile reinforcement core + flexible inner sheath + anti-torsion layer + abrasion-resistant outer sheath Max. conductor temperature: 90 °C energized / 250 °C short-circuit Ambient temperature: fixed installation -35 to +80 °C; mobile operation -25 to +80 °C Application: vertical reeling drums (240 m/min), cable supply systems (180 m/min) Max. tensile strength: 4000–6000 N Outer diameter / unit weight: 42×2.5 outer diameter 36.3–39.3 mm, 2.28 kg/m; 54×2.5 outer diameter 43.0–46.0 mm, 2.80 kg/m Standards: VDE 0250-814, VDE 0295

Heavy-duty drop cable for spreader baskets 300/500 V (36×2.5–54×2.5 mm², 14AWG range)
Rated voltage: 300/500 V (max. AC 550 V; AC test 2 kV) Size range: 36×2.5 / 42×2.5 / 48×2.5 / 54×2.5 mm² (corresponding to 14AWG) Conductor: special flexible copper conductor Construction: 6 cores per bundle + Kevlar central tensile core + EPR insulation + polychloroprene outer sheath 5GM3 Max. conductor temperature: EPR insulation 90 °C Ambient temperature: -20 to +80 °C Application: vertical suspension of spreader baskets (estimated minimum bending radius 650–800 mm) Max. tensile strength: 2000 N Outer diameter / unit weight: 36×2.5 outer diameter 38.0–41.0 mm, 2.60 kg/m; 54×2.5 outer diameter 47.0–51.0 mm, 4.10 kg/m Standards: VDE 0250-814

Heavy vertical cable for spreader baskets 300/500 V (36×3.3–54×3.3 mm², 12 AWG range)
Rated voltage: 300/500 V (max. AC 550 V; AC test 2 kV) Size range: 36×3.3 / 42×3.3 / 48×3.3 / 54×3.3 mm² (corresponding to 12 AWG) Conductor: special flexible copper conductor Construction: 6 cores per bundle + central Kevlar tensile core + EPR insulation + polychloroprene outer sheath 5GM3 Max. conductor temperature: EPR insulation 90 °C Ambient temperature: -20 to +80 °C Application: vertical suspension on spreader baskets (estimated min. bending radius 700–900 mm) Max. tensile strength: 2000 N Outer diameter / unit weight: 36×3.3 outer diameter 42.5–45.5 mm, 3.25 kg/m; 54×3.3 outer diameter 57.0–60.0 mm, 5.00 kg/m Applicable standards: VDE 0250-814

Power cable for festoon systems 0.6/1 kV (single-core 1×25–1×120 mm² range)
Rated voltage: 0.6/1 kV (max. AC 0.7/1.2 kV; AC test 3.5 kV) Size range: 1×25 / 1×35 / 1×50 / 1×70 / 1×95 / 1×120 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: EPR insulation 3GI3 + inner sheath + polychloroprene outer sheath 5GM3 Max. conductor temperature: energized 90 °C / short-circuit 250 °C Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min) Max. tensile strength: 375–1750 N Outer diameter / unit weight: 1×25 outer diameter 12.0–13.25 mm, 0.34 kg/m; 1×120 outer diameter 20.4–22.4 mm, 1.36 kg/m Applicable standards: VDE 0250-813, VDE 0295

Power cable for festoon systems 0.6/1 kV (4×4–4×25 mm² range)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 4×4 / 4×6 / 4×10 / 4×16 / 4×25 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: EPR insulation 3GI3 + inner sheath + polychloroprene outer sheath 5GM3 Max. conductor temperature: energized 90 °C / short-circuit 250 °C Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min) Max. tensile strength: 240–1500 N Outer diameter / unit weight: 4×4 outer diameter 15.0–16.4 mm, 0.36 kg/m; 4×25 outer diameter 27.5–29.5 mm, 1.65 kg/m Applicable standards: VDE 0250-813, VDE 0295

Power cable for festoon systems 0.6/1 kV (3×35+3×16/3–3×70+3×35/3 mm² range, 3+3 earth structure)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 3×35+3×16/3 / 3×50+3×25/3 / 3×70+3×35/3 mm² Conductor: VDE 0295 class 5 tinned copper conductor Construction: EPR insulation 3GI3 + inner sheath + polychloroprene outer sheath 5GM3 Max. conductor temperature: energized 90 °C / short-circuit 250 °C Ambient temperature: fixed installation -40 to +80 °C; mobile operation -25 to +80 °C Application: festoon systems (240 m/min) Max. tensile strength: 1575–3150 N Outer diameter / unit weight: 3×35+3×16/3 outer diameter 29.5–31.5 mm, 1.85 kg/m; 3×70+3×35/3 outer diameter 39.5–41.5 mm, 3.60 kg/m Applicable standards: VDE 0250-813, VDE 0295

Low-voltage reeling power cable 0.6/1 kV (4×2.5–4×10 mm² range)
Rated voltage: 0.6/1 kV (max. AC 0.7/1.2 kV; AC test 3.5 kV) Size range: 4×2.5 / 4×4 / 4×6 / 4×10 mm² Conductor: VDE 0295 class 5 flexible copper conductor Construction: HEPR insulation + inner sheath + anti-torsion braided layer + black polychloroprene outer sheath Max. conductor temperature: energized 85 °C / short-circuit 250 °C Ambient temperature: fixed installation -30 to +80 °C; mobile operation -20 to +60 °C Application: reeling/trailing on large machinery or cable reels (60 m/min, tensile 20 N/mm²) Max. tensile strength: 200–800 N Outer diameter / unit weight: 4×2.5 outer diameter 11.8–13.8 mm, 0.22 kg/m; 4×10 outer diameter 18.5–20.5 mm, 0.64 kg/m Applicable standards: VDE 0295

Low-voltage reeling power cable 0.6/1 kV (4×16–4×35 mm² range)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 4×16 / 4×25 / 4×35 mm² Conductor: VDE 0295 class 5 flexible copper conductor Construction: HEPR insulation + inner sheath + anti-torsion braided layer + black polychloroprene outer sheath Max. conductor temperature: energized 85 °C / short-circuit 250 °C Ambient temperature: fixed installation -30 to +80 °C; mobile operation -20 to +60 °C Application: reeling/trailing on large machinery or cable reels (60 m/min, tensile 20 N/mm²) Max. tensile strength: 1280–2800 N Outer diameter / unit weight: 4×16 outer diameter 21.8–24.0 mm, 0.95 kg/m; 4×35 outer diameter 28.5–31.0 mm, 1.80 kg/m Applicable standards: VDE 0295

Low-voltage reeling power cable 0.6/1 kV (3×50+3×25/3–3×95+3×50/3 mm² range, 3+3 earth structure)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 3×50+3×25/3 / 3×70+3×35/3 / 3×95+3×50/3 mm² Conductor: VDE 0295 class 5 flexible copper conductor Construction: HEPR insulation + inner sheath + torsion-resistant braid + black polychloroprene outer sheath Max. conductor temperature: 85 °C in operation / 250 °C short circuit Ambient temperature: fixed installation -30 to +80 °C; mobile operation -20 to +60 °C Application: reeling/trailing on large machinery or cable reels (60 m/min) Max. tensile strength: 3000 – 5700 N Outer diameter / weight per unit length: 3×50+3×25/3 outer diameter 33.0–36.0 mm, 2.40 kg/m; 3×95+3×50/3 outer diameter 41.0–44.0 mm, 4.05 kg/m Applicable standard: VDE 0295

Low-voltage reeling power cable 0.6/1 kV (3×120+3×70/3–3×240+3×120/3 mm² range, 3+3 earth construction)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 3×120+3×70/3 / 3×150+3×70/3 / 3×185+3×95/3 / 3×240+3×120/3 mm² Conductor: VDE 0295 class 5 flexible copper conductor Construction: HEPR insulation + inner sheath + torsion-resistant braid + black polychloroprene outer sheath Max. conductor temperature: 85 °C in operation / 250 °C short circuit Ambient temperature: fixed installation -30 to +80 °C; mobile operation -20 to +60 °C Application: reeling/trailing on large machinery or cable reels (60 m/min) Max. tensile strength: 7200 – 14400 N Outer diameter / weight per unit length: 3×120+3×70/3 outer diameter 45.0–48.0 mm, 5.10 kg/m; 3×240+3×120/3 outer diameter 62.5–66.5 mm, approx. 9.9 kg/m Applicable standard: VDE 0295

Low-voltage reeling power cable with fiber optics 0.6/1 kV (3×50+2×25/2+6FO–3×95+2×50/2+6FO range)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 3×50+2×25/2+6FO / 3×70+2×35/2+6FO / 3×95+2×50/2+6FO mm² Conductor: VDE 0295 class 5 flexible copper conductor Construction: HEPR insulation + inner sheath + torsion-resistant braid + black polychloroprene outer sheath + 6 multimode optical fibers Max. conductor temperature: 85 °C in operation / 250 °C short circuit Ambient temperature: fixed installation -30 to +80 °C; mobile operation -20 to +60 °C Application: reeling/trailing on large machinery or cable reels (60 m/min), power + fiber-optic data transmission Max. tensile strength: 3000 – 5700 N Outer diameter / weight per unit length: 3×50+2×25/2+6FO outer diameter 36.0–39.0 mm, 2.60 kg/m; 3×95+2×50/2+6FO outer diameter 43.0–46.0 mm, 4.40 kg/m Applicable standard: VDE 0295

High-strength low-voltage reeling power cable 0.6/1 kV (4×1.5–4×6 mm² range)
Rated voltage: 0.6/1 kV (max. AC 0.7/1.2 kV; AC test 3.5 kV) Size range: 4×1.5 / 4×2.5 / 4×4 / 4×6 mm² Conductor: VDE 0295 class 5 zinc-coated copper conductor Construction: EPR insulation 3GI3 + PCP inner sheath + torsion-resistant braid + polychloroprene outer sheath 5GM3 Max. conductor temperature: 90 °C in operation / 250 °C short circuit Ambient temperature: storage -40 to +80 °C; in operation -25 to +80 °C (K suffix: -40 to +50 °C) Application: single-row multi-layer reeling drums (200 m/min), cylindrical reeling drums (200 m/min) Max. tensile strength: 120 – 480 N Outer diameter / weight per unit length: 4×1.5 outer diameter 12.0–14.0 mm, 0.24 kg/m; 4×6 outer diameter 17.6–19.6 mm, 0.63 kg/m Applicable standards: VDE 0250-814, VDE 0295

High-strength low-voltage reeling power cable 0.6/1 kV (4×10–4×35 mm² range)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 4×10 / 4×16 / 4×25 / 4×35 mm² Conductor: VDE 0295 class 5 zinc-coated copper conductor Construction: EPR insulation 3GI3 + PCP inner sheath + torsion-resistant braid + polychloroprene outer sheath 5GM3 Max. conductor temperature: 90 °C in operation / 250 °C short circuit Ambient temperature: storage -40 to +80 °C; in operation -25 to +80 °C (K suffix: -40 to +50 °C) Application: single-row multi-layer reeling drums (200 m/min), cylindrical reeling drums (200 m/min) Max. tensile strength: 800 – 2800 N Outer diameter / weight per unit length: 4×10 outer diameter 21.5–23.5 mm, 0.94 kg/m; 4×35 outer diameter 32.5–35.0 mm, 2.54 kg/m Applicable standards: VDE 0250-814, VDE 0295

High-strength low-voltage reeling power cable 0.6/1 kV (3×50+3×25/3–3×240+3×120/3 mm² range, 3+3 earth construction)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 3×50+3×25/3 ~ 3×240+3×120/3 mm² (including 3×70+3×35/3, 3×95+3×50/3, 3×120+3×70/3, 3×150+3×70/3, 3×185+3×95/3) Conductor: VDE 0295 class 5 zinc-coated copper conductor Construction: EPR insulation 3GI3 + PCP inner sheath + torsion-resistant braid + polychloroprene outer sheath 5GM3 Max. conductor temperature: 90 °C in operation / 250 °C short circuit Ambient temperature: storage -40 to +80 °C; in operation -25 to +80 °C (K suffix: -40 to +50 °C) Application: single-row multi-layer reeling drums (200 m/min), cylindrical reeling drums (200 m/min) Max. tensile strength: 3000 – 14400 N Outer diameter / weight per unit length: 3×50+3×25/3 outer diameter 34.3–37.5 mm, 2.75 kg/m; 3×240+3×120/3 outer diameter 66.0–70.7 mm, 12.0 kg/m Applicable standards: VDE 0250-814, VDE 0295

High-strength low-voltage reeling power cable 0.6/1 kV (five-core 5×1.5–5×16 mm² range)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 5×1.5 / 5×2.5 / 5×4 / 5×6 / 5×10 / 5×16 mm² Conductor: VDE 0295 class 5 zinc-coated copper conductor Construction: EPR insulation 3GI3 + PCP inner sheath + torsion-resistant braid + polychloroprene outer sheath 5GM3 Max. conductor temperature: 90 °C in operation / 250 °C short circuit Ambient temperature: storage -40 to +80 °C; in operation -25 to +80 °C (K suffix: -40 to +50 °C) Application: single-row multi-layer reeling drums (200 m/min), cylindrical reeling drums (200 m/min) Max. tensile strength: 150 – 1600 N Outer diameter / weight per unit length: 5×1.5 outer diameter 12.8–14.8 mm, 0.32 kg/m; 5×16 outer diameter 27.8–29.8 mm, 1.55 kg/m Applicable standards: VDE 0250-814, VDE 0295

High-strength low-voltage reeling power cable 0.6/1 kV (power + control composite 4×10+4×2.5–4×35+4×2.5 mm² range, mechanical clamp structure)
Rated voltage: 0.6/1 kV (AC test 3.5 kV) Size range: 4×10+4×2.5 / 4×16+4×2.5 / 4×25+4×2.5 / 4×35+4×2.5 mm² Conductor: VDE 0295 class 5 zinc-coated copper conductor Structure: EPR insulation 3GI3 + PCP inner sheath + anti-torsion mesh layer + polychloroprene outer sheath 5GM3, power + control composite cabling Maximum conductor temperature: energized 90 °C / short circuit 250 °C Ambient temperature: storage -40 ~ +80 °C; energized -25 ~ +80 °C (K suffix -40 ~ +50 °C) Application: single-row multi-layer reeling (200 m/min), drum reeling (200 m/min) Maximum tensile strength: 800 – 2800 N Outer diameter/unit weight: 4×10+4×2.5 outer diameter 23.2–25.2 mm, 1.03 kg/m; 4×35+4×2.5 outer diameter 33.0–36.0 mm, 2.50 kg/m Applicable standards: VDE 0250-814, VDE 0295

High-voltage reeling power cable 3.6/6 kV (3×25+3×10–3×120+3×25 mm² range, enhanced tensile/torsional/high-speed)
Rated voltage: 3.6/6 kV (max. AC 4.2/7.2 kV; AC test 11 kV) Size range: 3×25+3×10 / 3×35+3×10 / 3×50+3×10 / 3×70+3×16 / 3×95+3×16 / 3×120+3×25 mm² Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor with semi-conductive layer + inner sheath + anti-torsion mesh layer + red synthetic rubber outer sheath Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -25 ~ +60 °C Application: single-row multi-layer reeling: end feed 300 m/min, center feed 200 m/min Maximum tensile strength: static 3000 – 7500 N (dynamic 4125 – 10800 N) Outer diameter/unit weight: 3×25+3×10 outer diameter 42.5–45.5 mm, 2.56 kg/m; 3×120+3×25 outer diameter 60.6–64.6 mm, 6.80 kg/m Applicable standards: VDE 0250-813, VDE 0295, VDE 0472-512

High-voltage reeling power cable 6/10 kV (3×25+3×10–3×120+3×25 mm² range, enhanced tensile/torsional/high-speed)
Rated voltage: 6/10 kV (max. AC 6.9/12 kV; AC test 17 kV) Size range: 3×25+3×10 ~ 3×120+3×25 mm² (same as 3.6/6 kV range) Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor with semi-conductive layer + inner sheath + anti-torsion mesh layer + red synthetic rubber outer sheath Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -25 ~ +60 °C Application: single-row multi-layer reeling: end feed 300 m/min, center feed 200 m/min Maximum tensile strength: static 3000 – 7500 N (dynamic 4125 – 10800 N) Outer diameter/unit weight: 3×25+3×10 outer diameter 42.5–45.5 mm, 2.56 kg/m; 3×120+3×25 outer diameter 60.6–64.6 mm, 6.95 kg/m Applicable standards: VDE 0250-813, VDE 0295, VDE 0472-512

High-voltage reeling power cable 8.7/15 kV (3×25+3×10–3×120+3×25 mm² range, enhanced tensile/torsional/high-speed)
Rated voltage: 8.7/15 kV (max. AC 10.4/18 kV; AC test 24 kV) Size range: 3×25+3×10 ~ 3×120+3×25 mm² (same as 3.6/6 kV range) Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor with semi-conductive layer + inner sheath + anti-torsion mesh layer + red synthetic rubber outer sheath Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -25 ~ +60 °C Application: single-row multi-layer reeling: end feed 300 m/min, center feed 200 m/min Maximum tensile strength: static 3000 – 7500 N (dynamic 4125 – 10800 N) Outer diameter/unit weight: 3×25+3×10 outer diameter 45.2–48.2 mm, 2.75 kg/m; 3×120+3×25 outer diameter 64.5–68.5 mm, 7.70 kg/m Applicable standards: VDE 0250-813, VDE 0295, VDE 0472-512

High-strength high-voltage reeling power cable 3.6/6 kV (3×25+3×10–3×185+3×35 mm² range)
Rated voltage: 3.6/6 kV (max. AC 4.2/7.2 kV; AC test 11 kV) Size range: 3×25+3×10 ~ 3×185+3×35 mm² (including 3×35+3×10, 3×50+3×10, 3×70+3×16, 3×95+3×16, 3×120+3×25, 3×150+3×25) Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor with semi-conductive layer + inner sheath + anti-torsion mesh layer + red polychloroprene outer sheath 5GM3 Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -30 ~ +80 °C Application: single-row multi-layer reeling (200 m/min), drum reeling (180 m/min) Maximum tensile strength: static 1500 – 11100 N (dynamic 2250 – 13800 N) Outer diameter/unit weight: 3×25+3×10 outer diameter 37.3–40.3 mm, 2.30 kg/m; 3×185+3×35 outer diameter 66.0–70.0 mm, 9.60 kg/m Applicable standards: VDE 0250-814, VDE 0295, VDE 0472-512

High-strength high-voltage reeling power cable 6/10 kV (3×25+3×10–3×185+3×35 mm² range)
Rated voltage: 6/10 kV (max. AC 6.9/12 kV; AC test 17 kV) Size range: 3×25+3×10 ~ 3×185+3×35 mm² (same as 3.6/6 kV range) Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor with semi-conductive layer + inner sheath + anti-torsion mesh layer + red polychloroprene outer sheath 5GM3 Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -30 ~ +80 °C Application: single-row multi-layer reeling (200 m/min), drum reeling (180 m/min) Maximum tensile strength: static 1500 – 11100 N (dynamic 2250 – 13800 N) Outer diameter/unit weight: 3×50+3×10 outer diameter 44.8–47.8 mm, 3.47 kg/m; 3×185+3×35 outer diameter 67.5–71.5 mm, 9.70 kg/m Applicable standards: VDE 0250-814, VDE 0295, VDE 0472-512

High-strength high-voltage reeling power cable with optical fiber 3.6/6 kV (3×25+2×25/2+6FO–3×185+2×95/2+6FO range)
Rated voltage: 3.6/6 kV (max. AC 4.2/7.2 kV; AC test 11 kV) Size range: 3×25+2×25/2+6FO ~ 3×185+2×95/2+6FO mm² Conductor: VDE 0295 class 5 copper conductor Structure: semi-conductive layer + HEPR insulation + grounding conductor + optical fiber + inner sheath + anti-torsion mesh layer + red polychloroprene outer sheath 5GM3 Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -30 ~ +80 °C Application: single-row multi-layer reeling (200 m/min), drum reeling (180 m/min), power + optical fiber data transmission Maximum tensile strength: static 1500 – 11100 N (dynamic 2250 – 13800 N) Outer diameter/unit weight: 3×25+2×25/2+6FO outer diameter 37.5–40.5 mm, 2.40 kg/m; 3×185+2×95/2+6FO outer diameter 66.0–70.0 mm, 9.60 kg/m Applicable standards: VDE 0250-814, VDE 0295, VDE 0472-512

High-strength high-voltage reeling power cable with optical fiber 6/10 kV (3×25+2×25/2+6FO–3×185+2×95/2+6FO range)
Rated voltage: 6/10 kV (max. AC 6.9/12 kV; AC test 17 kV) Size range: 3×25+2×25/2+6FO ~ 3×185+2×95/2+6FO mm² Conductor: VDE 0295 class 5 copper conductor Construction: semiconductive layer + HEPR insulation + grounding conductor + optical fiber + inner sheath + anti-torsion braided layer + red polychloroprene outer sheath 5GM3 Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -30 ~ +80 °C Application: single-row multi-layer reeling drum (200 m/min), cylindrical reeling drum (180 m/min), power + fiber-optic data transmission Maximum tensile strength: static 1500 – 11100 N (dynamic 2250 – 13800 N) Outer diameter/unit weight: 3×50+2×25/2+6FO outer diameter 39.5–42.5 mm, 2.51 kg/m; 3×185+2×95/2+6FO outer diameter 69.0–73.0 mm, 10.00 kg/m Standards: VDE 0250-814, VDE 0295, VDE 0472-512

High-voltage flat reeling power cable 3.6/6 kV (3×35+35E–3×50+50E, for reeling drums/reels)
Rated voltage: 3.6/6 kV / 6/10 kV (AC test 11 / 17 kV) Size range: 3×35+35E / 3×50+50E mm² (two ratings: 3.6/6 kV and 6/10 kV; e.g., 3.6/6 kV 3×50+50E max. dimensions 93×32.5 mm) Conductor: copper conductor (shielded three-phase conductor) Construction: shielded three-phase conductor + red PCP outer sheath 5GM3, flat construction Maximum conductor temperature: current-carrying 90 °C / short circuit 250 °C Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -25 ~ +80 °C Application: single-row multi-layer reeling drum (reel), 180 m/min Maximum tensile strength: 1575 – 2250 N Outer diameter/unit weight: 3×35+35E max. dimensions 87×30.0 mm, 4.08 kg/m; 3×50+50E max. dimensions 93×32.5 mm, 4.75 kg/m

High-voltage flat reeling power cable 3.6/6 kV (with optical fiber 3×35+4×25/4E+12FO–3×50+4×25/4E+12FO, for reeling drums/reels)
Rated voltage: 3.6/6 kV / 6/10 kV (AC test 11 / 17 kV) Size range: 3×35+4×25/4E+OFE12×62.5/125 / 3×50+4×25/4E+OFE12×62.5/125 mm² (two ratings: 3.6/6 kV and 6/10 kV) Conductor: copper conductor (shielded three-phase conductor) Construction: shielded three-phase conductor + grounding core + optical fiber + red PCP outer sheath 5GM3, flat construction Maximum conductor temperature: current-carrying 90 °C / short circuit 250 °C Ambient temperature: fixed installation -40 ~ +80 °C; mobile operation -25 ~ +80 °C Application: single-row multi-layer reeling drum (reel), 180 m/min Maximum tensile strength: 1575 – 2250 N Outer diameter/unit weight: 3×35+4×25/4E+12FO max. dimensions 87×30.0 mm, 3.97 kg/m; 3×50+4×25/4E+12FO max. dimensions 93×32.5 mm, 4.85 kg/m

LED Sports Floodlight 1000W (P7 series, stadium distribution)
Model: DMPL-P7B1-1000 (B1 sports distribution) Power: 1000 W Luminous flux: 135000 ±5% lm (135 lm/W; efficacy class 130-160 lm/W) LEDs: 696 pcs LUMILEDS 3535 CCT: 4000±300K / 5000±300K / 5700±300K / 6500±300K CRI: ≥80 (3535) / ≥70 (5050); SDCM ≤5; TLCI ≥70 Beam angle: 15°/35° (B type); 19°/25°/40°/55°/90°/95°×55° options Input: 198-462 VAC, 47-63 Hz Operating temperature: -30~+50°C (storage -30~+60°C) Housing: magnesium alloy + ADC12 + stainless steel + glass + optical PC Protection: IP66 Lifespan: >100,000 h

LED High Mast Floodlight 720W (P5 series, Type A)
Power: 720 W (Type A 150-1200 W; Type B 600-1440 W) Luminous flux: 104400 lm (140-145 lm/W; Type B ≥140 lm/W) CCT: 3000±300K / 4000±300K / 5700±300K CRI: ≥70 Beam angle: 15°/40° (multi-angle options) Input: 100-240 VAC (440 V option), 47-63 Hz Operating temperature: -30~+60°C Housing: die-cast aluminum + PC Protection: IP67, IK09 Lifespan: >100,000 h

LED High Mast Floodlight 480W (P4 series)
Power: 480 W (range 240-960 W) Luminous flux: 64800 ±5% lm (≥135 lm/W) LED: LUMILEDS 3030 CCT: 3000±300K / 4000±300K / 5700±300K CRI: ≥70 Beam angle: 20°×15° / 45° / 60° / 90° / 120° / asymmetric 105°×55° Input: 100-240 VAC (440 VAC option), 47-63 Hz Operating temperature: -20~+60°C Housing: ADC12 aluminum + PC + tempered glass Protection: IP67, IK09 Lifespan: >100,000 h

LED High Bay Light 150W (H9 series, graphene heat sink)
Power: 150 W (range 100-200 W) Luminous flux: 21000 ±5% lm (140 lm/W class; 160 lm/W class available) CCT: 4000±300K / 5000±300K / 6500±300K CRI: ≥70 Beam angle: 60° / 90° / 120° Input: 100-277 VAC, 50/60 Hz Operating temperature: -20~+45°C Housing: PC + graphene composite heat sink Protection: IP65 Lifespan: >100,000 h

LED High Bay Light 150W (H8 series)
Power: 150 W (range 100-200 W) Luminous flux: 23250 lm (155 lm/W) CCT: 3000±300K / 4000±300K / 5000±300K / 5700±300K CRI: ≥70 Beam angle: 60° / 90° / 110° Input: 100-240 VAC, 47-63 Hz Operating temperature: -30~+45°C Housing: ADC12 die-cast aluminum + PC Protection: IP65, IK09 Lifespan: >100,000 h